Critical
Summit WM-Series WLAN Switch and Altitude Access Point Software Version 1.0 User Guide
197
STARTUP_MANAGER
SECURITY_MANAGER
Severity Critical
Log Message Error binding to listener socket. Will not be able to communicate with Apache server.
Description Inter-component communication failure.
Action Verify that the web server is still running. If it is, re-start the security manager process to
clear the problem.
SECURITY_MANAGER
Severity Critical
Log Message Listen call failed. Will not be able to communicate with Apache Server.
Description Inter-component communication failure.
Action Verify that the web server is still running. If it is, re-start the security manager process to
clear the problem.
SECURITY_MANAGER
Severity Critical
Log Message Socket call failed. Will not be able to communicate with specific component.
Description Inter-component communication failure.
Action Indicates that a service the Security Manager depends on has failed. There may be another
event from the Start-up Manager indicating that a service has been restarted.
STARTUP_MANAGER
Severity Critical
Log Message Failed attempting to start router ports. System reboot initiated.
Description Hardware initialization error.
Action The router ports could not be initialized. The system reboots to attempt recovery. If the
problem does not clear, Contact service as the system may need to be replaced.
STARTUP_MANAGER
Severity Critical
Log Message Internal connection to router ports lost. Restart initiated.
Description Hardware failure.
Action Communication path to the router ports is lost. Reboot the system to attempt recovery.