ExtremeWare EPICenter Software Installation and User Guide 16-11
Viewing Predefined EPICenter Reports
conditional statement based on the values of relevant variables in the ExtremeWare
EPICenter database.
The following reports provide filtering:
Interface Report
Alarm Log
Event Log
Config Mgmt Log
These reports provide a set of fields at the bottom of the report similar to the ones shown
in Figure 16-3.
Figure 16-3: Report filter specification
To create a filter, follow these steps:
1 In thefirst field,selectthe variableto use in thefilter.Thevariables from which youcan
choose are based on the column headings in the report, and depend on the type of
report you are viewing.
2 In the second field, select a comparison operator. You canchoose from the following
comparison operators:
> (greater than)
<(lessthan)
<= (greater than orequal)
>= (less than or equal)
!= (not equal)
=(equal)